Welcome to Shanghai HI RUN system control Co., Ltd!

Contact us Collection site Online Message

National Service Hotline 021-63526338
  • Home
  • About Us
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/about/ —— About Us {/dede:channel}
  • Product Center
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Product Center/ —— Product Center {/dede:channel}
  • News Information
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/News Information/ —— News Information {/dede:channel}
  • Engineering Case
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Engineering Case/ —— Engineering Case {/dede:channel}
  • Sales Outlets
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Sales Outlets/ —— Sales Outlets {/dede:channel}
  • Download
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /Download/ —— Download {/dede:channel}
  • Contact Us
  • {dede:field name='typeurl'/}'——{dede:field name='typename'/} {dede:channel type='son' noself='yes' } /en/Contact Us/ —— Contact Us {/dede:channel}
  • Online Message

Hot keyword search:

Primry Circuit Cables Location:Home> > English > Product Center > Airport Cables > Primry Circuit Cables >

RG7H1R for Airport Lighting Cables

RG7H1R for Airport Lighting Cables    

Applications

These cables are used as airfield lighting equipment primary cables for the series circuit connecting the Constant Current Regulators and the isolasting transformers, and between the isolating transformers.

Standards

ENV 50213

Construction

Conductor: Compact stranded bare copper conductor.
Inner Semi-Conductor: Extruded semi-conducting compound.
Insulation: High module rubber compound, G7 type.
Outer Semi-Conductor: Extruded semi-conducting compound.
Shield: Bare copper tapes.
Sheath: PVC.

Technical Data

Rated Voltage Uo/U (Um)

3.6/6kV

Maximum Conductor Temperature

90℃

Short Circuit Temperature

250℃

Operating Temperatures

0℃~+90℃

Minimum Bending Radius

15×OD

Flame Retardant

Yes

Dimensions and Weight

Construction

Nominal Insulation
Thickness

Minimum Shield
Thickness

Nominal Sheath
Thickness

Nominal Overall
Diameter

Nominal Weight

No. ×mm²

mm

mm

mm

mm

kg/km

1×10

2.3

0.075

1.4

14.0

305